topblog Ivoire blogs

07/08/2017

How to program PCM with As-Built data with Ford IDS software

To program the PCM with As-built information via Ford IDS software:

 

Enter the Module Programming menu in the IDS

Select As-built and then the PCM

If the PCM is not listed in the As-built tab, use the following process to manually enter the information.

Select the IDS logo in the upper left corner of the screen.

Select the Pocket knife in the lower left corner of the screen.

Select “Update/Special Functions” from the Miscellaneous menu.

 Ford IDS software update function

 

Enter 53061 into the blue box and click the tick.

Return to the Module Programming menu and select PMI then the PCM.

Follow the on-screen prompts and enter the As-built data when the IDS prompts for it. This data is available from the OASIS report for this VIN under the As-built tab. It has also been provided below for your convenience.

Complete the PMI process by continuing with the on-screen directions.

Complete the PMI process by continuing with the on-screen directions.

To get As Built Data, go to Motorcraftservice.com

Under Non-Subscription Resources, click on Quick Guides.

13 dot points down you will fine, “Module Build Data (As-Built)”

Enter “Module Build Data”

Enter the VIN# then submit. As Built Data will then be displayed in IDS interface.

 

 

Some codes/info listed here as an example:

 

Use at your own risk!

 

00008 – IDENT_APPLY_PATCHES_VIA_FLOPPY

00009 – IDENT_UPDATE_PTU_FROM_FLOPPY

32287 – IDENT_LAUNCH_APP_MCP_REST

60503 – IDENT_LAUNCH_REGRESSION_RECORDER

27001 – IDENT_LAUNCH_FT_EOL_CP_MZ_01

32247 – IDENT_LAUNCH_SERVICE_ROUT

24040 – IDENT_ENABLE_VALIDATION_MODE

24041 – IDENT_DISABLE_VALIDATION_MODE

23761 – IDENT_LAUNCH_APP_FT_DATA_REC

81105 – IDENT_LAUNCH_APP_TSBSSMLIST

53061 – IDENT_IGNORE_MCP_INHALE

26503 – IDENT_LAUNCH_APP_VVAG

81104 – IDENT_LAUNCH_APP_FTW_SHIP_MODE_01

29124 – IDENT_TOGGLE_FORD_EXTRANET_INTRANET_URLS

60274 – IDENT_LAUNCH_CCC_ENGINEERING_APP

32227 – IDENT_LAUNCH_PROPSHAFT_BAL_APP

48712 – IDENT_LAUNCH_GENERIC_RCM_CONFIG_APP

28487 – IDENT_LAUNCH_FT_ICCMSP_MZ_01_APP

28097 – IDENT_TOGGLE_BATTERY_MONITORING

70263 – IDENT_LAUNCH_GENERIC_DIAG

71863 – IDENT_MCP1

63296 – IDENT_LAUNCH_FTW_RKE_MODE_01_APP

08080 – IDENT_LAUNCH_DETAILED_NETWORK_DIAG

32267 – IDENT_LAUNCH_APP_ENG_SUPPORT_TOOL

 

 

28/07/2017

Free Download Rheingold 3.55.11 ISTA-P 3.58.3.003 torrent

Free download

Rheingold 3.55.11 Standalone ISTA-P 3.58.3.003 torrent (being tested)

ISTA-D 3.54.12 ISTA-P 3.58.0.500 Software (tested, cracked)

 

BMW software is offered here to free download, to work with INPA cable or BMW ICOM A2 for BMW diagnosis and programming.

 

Standalone versions of ISTA-D and ISTA-P.
SQLiteDBs 3.55.14, including EN, DE, RU, OTHER.
Workable device:

BMW K+dcan inpa cable

ICOM A2 emulator

Rheingold-3.55.11-ISTA-P-3.58.3.003 (1)

 

Rheingold-3.55.11-ISTA-P-3.58.3.003 (2)


For unpack archives use 7-zip 15.12 or Winrar 5.30 and higher ( unblock archives if needed ).

Install:
Ediabas, Java, vcredist 2010 x86 x64, vcredist 2013 x86 x64, vs90_piaredist, net framework 4.5.2 or higher.

Rheingold :
Unpack, for examle in D:Rheingold, unpack and copy SQLiteDBs in RheingoldSQLiteDBs, run RCleanerV4.3.exe from Tools folder.
Apply ISTA-D Reg Fix for your system (x86 or x64) from Tools folder.
Run D:RheingoldTesterGUIbinReleaseISTAGUI.exe.
If ask license, enter it from License.txt file. Enter 1 in ISIS field, ignore error and press ok.

ISTA-P :
Install Networktool.exe, for K-DCAN cable. (ICOM doesn’t need it).
Unpack in the root of any drive, for example D:ISTA-P.
Run BMW ISTA-P Loader V4.9.exe from Tools folder.
Choose language, resolution and expert mode options. Ignore message about resolution.

This post source from Car OBD2 Tools global one-stop shopping supplier ---OBDexress.co.uk Official technical blog :http://blog.obdexpress.co.uk/2017/07/28/rheingold-3-55-11...

27/07/2017

OPCOM Op-com Firmware 1.60 1.59 1.45 1.39 Update User Manual

Here’s the OPCOM firmware update user manual. The op-com software version use one or other firmware version as fw 1.33, fw 1.39, fw 1.41, fw 1.43, fw 1.44 fw 1.45, fw 1.47 fw 1.59 fw 1.60 ( the last one ).

 

OPCOM firmware introduction:

OP-COM China clone ( op-com 100219a ) from 2009 use fw 1.39 – do not use other firmware

 

OP-COM software from 2011 use fw1.44

 

OP-COM software from 2012 used fw 1.45 and the software released at the end of that year used fw1.47

 

OP-COm software from 2014 used fw1.59 (fw 1.45 & 1.59 come with the same pcb)

 

VAUX-COm version, Romanian and German version of OP-COM used fw1.60

 

So the difference it is not in the firmware as 1.44, 1.45, the difference it is in the software version

 

NOTE:

– With other words if you have an op-com tool that it has firmware 1.39 and you’ll try to use it

– with for instance OP-COM 131223c English version the software will upgrade the firmware of your interface to the version that its need- to 1.59

– If then you try one of the version in Romanian/ German or vaux-com version 131223 the software will upgrade the firmware of the tool to the fw 1.60

 

So now in conclusion. You do not need to change the firmware of your tool with one or other. You only need to use the necessary firmware for the software version that you are using it.

OPCOM firmware update:

changing (upgrade or downgrade) firmware version in op-com chinese clone is at risk – you’ll damage the tool and it will not work anymore

 

The only way to change Opcom firmware is

 

to replace the MCU with a original Microchip PIC18F458

remove 2 component from PCB

Remake a connection on bord and cut another one

Then reprogram the new brand chip PIC18F458 and you can have a brand new clone that will be available to upgrade the firmware of the interface

NOTE:

– The firmware must be the one that it is required by the software version

– Do not use other one because will not 100% correct

– A normal clone not model cannot works with the Model software that works with as we named HQ clone

– This not depend on the ept or firmware and depend on the FTDI ID and PIC dump. All it is about a marriaged dump of PIC MCU with the FTDI ID – a uniq combination

– firmware 1.59 and 1.60 update is most populous:

 

Good luck